In the stage equipment market of the United States, flame retardant safety is a core requirement for product design and sales. For stage curtains, meeting both the NFPA701-2023 method1 and TB117-2013 flame retardant standards.
1. NFPA701-2023: The Technical Benchmark for Theater Security
1.1 Application scope:
Method 1 is applicable to single-layer or lightweight (≤700g/m²) textiles and is a mandatory access test for scenarios such as stage curtains and theater soft furnishings. This test indicates that the material can effectively suppress the spread of flames when exposed to small-scale open flames, meeting the basic fire safety requirements.
1.2 Test process:
The sample was vertically suspended on a dedicated test rack, with the bottom edge exposed to a standard methane flame (flame height 38mm) for 12 seconds.
After removing the fire source, observe and record .
1.3 Judgment criteria:
Self-extinguishing time: After the fire source is removed, the flame must be completely extinguished within 2 seconds.
Burning length: The carbonization or burning marks of the sample shall not exceed 152mm (6 inches) above the bottom edge of the sample.
Droplets: Fragments that drip during the burning process must not ignite the cotton pad below (a standard cotton pad should be placed under the test stand).

TB117-2013
Test result of our 22oz Stage Velour Velvet Curtain fabric
2. TB117-2013: The Extended Impact of California's Flame Retardant Regulations
Although TB117 is mainly aimed at the flame retardancy of filling materials for California soft furniture, many American theater purchasers will make it an additional requirement for curtain procurement.
2.1 Pass/fail criteria:
1. A single mock-up test specimen fails to meet the requirements of this test procedure if any of
the following criteria occurs:
a) The mock-up test specimen continues to smolder after the 45 minute test duration.
b) A vertical char length (measured as specified in step 11.9 of ASTM E1353-08a e1) of more than 1.8 inches(45 mm) develops on the cover fabrics.
c) The mock-up test specimen transitions to open flaming.
The cover fabric passes the test if three initial mock-up specimens pass the test.
If more than one initial specimen fails, the cover fabric fails the test.
If any one of the three initial specimens fails, repeat the test on additional three specimens.
If all three additional specimens pass the test, the cover fabric passes the test. lf any one of the additional three specimens fails, the cover fabric fails the test.

NFPA701-2023
Test result of our 22oz Stage Velour Velvet Curtain fabric
Under the strict framework of NFPA701-2023 Method 1 and TB117-2013 standards, our flame-retardant velvet stage curtain has passed the tests of authoritative third-party laboratories(SGS). All test results are 100% in line with the limit requirements of the two standards - the self-extinguishing time of combustion is ≤2 seconds, the carbonization length is ≤45mm, and there is no risk of smoldering or ignition by dripping substances.
We promise:
Compliance and transparency: We can provide customers with complete test reports (including original laboratory data and video records), covering all the results of the NFPA701 method 1 test and the TB117 section 1 test.
Customized services: We support the issuance of customized reports based on the customer's specified requirements (such as customer's name, theater name and project number), helping you quickly pass the procurement review and fire protection acceptance.
Rapid response: From the confirmation of testing requirements to the delivery of reports, the entire cycle can be compressed to 7 working days. For urgent projects, an expedited channel can be activated.
Contact us to obtain a complete sample of the test report and customize a dedicated safety solution for your stage!